CMS8000 Patient Monitor with Printer (PR, NIBP, SpO2, Temp, ECG)
$44.75
$60.41
Description SPECIFICATIONS: Features: 12.1″ TFT colour LCD, 15-language interface. Finish all operations by keys and knobs. Be applicable for adult, pediatric and neonatal for all round monitoring. Elegant appearance, clear masks, standard interface, oxygen graph, trend graph, big characters, other BED observation, which are convenient for users. Sync display of 8-lead ECG. Monitoring content, can speed, volume and output contents can be set optionally. Waveform and parameters colour can be set optionally. Alarm items: Technical alarm, 71 physiological alarms and 60 arrhythmia alarms. Adopt digital Sp02 technology, which has strong anti-interference and anti-weak filling capability. Trend review for 480-hours, review for 2400 groups of BP data, Storage review of 72-hour ECG waveform with the mounting SD card. Calculation of drug concentration. Network function: Connect central monitoring station, other bed observation and software updating. Achieve data storage and software updating by USB interface. Connection mode: Wired, WIFI and 3G. Built-in rechargeable battery for uninterrupted monitoring. Print ECG, Sp02, RESP, BP and TEMP data with one key. Anti-high frequency surgical unit, defibrillation, proof (requirement for special leads). Analysis function for heart variability (HRV) (optional). Standard parameters: ECG, RESP, NIBP, Sp02 and dual channel temp. Optional functions: IBP, CO2, built in printer, moving bracket, hanging bracket, VGA output, 12-lead and vehicle power. The product has passed FDA certification in America and CE certification in Europe. NIBP: Method: Oscillometric. Mode: Manual, Auto, Continual. Measurement interval in Auto mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 240, 480, 960 minutes. Measuring period in continual mode: 5min. Alarm type: SYS, DIA, MEAN. Measuring and alarm range: Adult mode: SYS: 40-270 mmHg; DIA: 10-215 mmHg; MEAN: 20-235 mmHg. Pediatric mode: SYS: 40-200 mmHg; DIA: 10-150 mmHg; MEAN: 20-165 mmHg. Neonatal mode: SYS: 40-135 mmHg; DIA: 10-100 mmHg; MEAN: 20-110 mmHg. Resolution: Pressure: 1 mmHg. Accuracy: Pressure Mean error: ±5mmHg. Maximum Standard deviation: 8mmHg. Software overpressure protection Adult mode: 297 ±3mmHg. Pediatric Mode: 240 ±3mmHg. Neonatal Mode: 147 ±3mmHg. SpO2: Measuring Range: 0% – 100%. Alarm Range: 0% – 100% Resolution: 1% Accuracy: 70% – 100% ±2%; 0%-69% unspecified. Actualization interval: about 1Sec. Alarm Delay: 10Sec. Pulse rate: Measuring and Alarm range: 30-250bpm. Resolution: 1bpm Accuracy: ±2bpm Temp: Channel: 2 Measuring and Alarm range: 0-50 °C. Resolution: 0.1°C. Accuracy: ±0.1°C. Actualization interval: about 1 Sec. Average time constant: < 10 sec. ECG: Lead mode: 5 leads (R, L, F, N C or RA, LA, LL, RL, V). Lead selection: I, II, III, aVR, aVL, aVF, V. Waveform: 2ch. Lead mode: 3 Leads (R, L, F or RA, LA, LL). Lead selection: I, II, III. Waveform: 1 ch. Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV. HR: Measure and Alarm range: Adult 15-300bpm. Neo/Ped: 15-350 bpm. Accuracy: ±1% or ±1bpm, whichever is greater. Resolution: 1bpm. Sensitivity: >200uV p-p. Differential Input Language Impedance: > 5 M Ω. Calibration Signal: 1 mV (Vp-p), ±5% Accuracy. ST Segment Monitoring Range Measurement and Alarm: -2.0- 2.0mV. Accuracy: -0.8- 0.8mV, 0.04mV or 10% of which is greater; Other unspecified. Tall T – wave rejection capabilitu: 1.2mV.
Patient Monitors